<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-12 13-15-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 4/5, 64 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 56 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 19064 0,8550
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,3 dBr 2,82 dBr 5,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 2 (Affairs) 0 1 1 1 13:15, 12.05.2025
RT
"YleX Etusivu: Sikke "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 0,8550 Acquired: 2025/05/12 13.14.16 Total samples: 19064 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,0 dBr MIN: 0,3 dBr AVE: 2,82 dBr % above 12,2 dBr: 0,0 Last value: 2,9 dBr (2025/05/12 13.14.16) 13.00 13.02 13.04 13.06 13.08 13.10 13.12 13.14 0 2 4 6 Pm [dBr]